# Sealed slab and vapour barrier

Passive · New build only

One of 2 ways to meet this need. Cost, carbon, footprint and rankings are relative to other solutions for the same need, not absolute.

A sealed floor slab laid over a tough plastic sheet that blocks gases rising from the ground. Radon and damp from the soil are stopped at the floor. It is simpler than extracting the gas with a sump, but less certain to keep it out.

## Build it

- [Capillary Break Beneath Slab - Polyethylene Sheeting or Rigid Insulation over Aggregate or Sand and Geotextile Mat](https://basc.pnnl.gov/resource-guides/capillary-break-beneath-slab-polyethylene-sheeting-or-rigid-insulation-over) Guide: a capillary break under a slab. Building America Solution Center · English

- **Cost:** Low
- **Upkeep:** None
- **Skill to build:** Basic
- **Lifespan:** Vapour barrier membrane: 30-50+ years if undisturbed, similar failure mode to the airtight membrane
- **Embodied carbon:** Low
- **Space / material use:** Low
- **When it gives:** None
- **Skill to repair:** Basic
- **Regulation (FR example):** When the home is sold or let, radon risk information is compulsory in category-3 radon-potential communes. Mitigation needs no permit; it is expected where measured levels are high. [Source: service-public.gouv.fr](https://www.service-public.gouv.fr/particuliers/vosdroits/F12239)

## Inputs

none

## Outputs

- [Improved indoor air](https://lowtechgraph.org/en/resource/improved-indoor-air)

## Assess it · 2 ways to meet this need

- **Sealed slab and vapour barrier** (This page)
   Can I use it? Not in a flat · New build only
   What does it cost me? Upfront cost: Low · Skill to build: Basic · Upkeep: None · Change to daily life: None · Works without the grid: Yes
   Choose it if you are pouring a new slab and want a simple barrier against soil gas and damp.
- [Sub-slab depressurisation / radon sump](https://lowtechgraph.org/en/solution/sub-slab-depressurisation-radon-sump)
   Can I use it? Not in a flat · No rebuilding needed
   What does it cost me? Upfront cost: Medium · Skill to build: Intermediate · Upkeep: Light · Change to daily life: None · Works without the grid: No
   Choose it if radon is known in your area and you want it drawn away before it reaches the rooms.

## Sources

- [NAHB / Bank of America Home Equity, "Study of Life Expectancy of Home Components" (February 2007), Table 1: insulation and infiltration barriers, lifetime if not punctured and kept dry](https://standards.nsf.org/higherlogic/ws/public/download/348/NAHB%202007%20StudyUseful%20Life%20of%20Home%20Components.pdf)

## Limitations of this page

We don’t list sizing or quantities, as the yield of each technique depends on the quality of its build. The catalogue compares options but doesn’t dimension them. Regulatory notes are indicative, with a French example, and need to be confirmed locally.