> Lowtech Graph · https://lowtechgraph.org/en/solution/permitted-discharge-to-soil-drainage-field · [fr](https://lowtechgraph.org/fr/solution/rejet-autorise-vers-un-epandage.md)  
> The catalogue content is published under CC BY-SA 4.0: use it, adapt it, credit it, and share what you build from it on the same terms.

[Greywater (sink and shower)](https://lowtechgraph.org/en/need/greywater-management) › [Letting it go safely](https://lowtechgraph.org/en/need/greywater-management/safe-discharge)

Lowtech Graph lists low-tech options for every need of a home. Here you can compare them, find tutorials to build them, and combine them into a circular system.

# Permitted discharge to soil/drainage field

Passive

Note: Cost, carbon and footprint are broad judgements against comparable building approaches, not measured figures.

## What your site needs

Soil percolation rate and area sufficient for a code-compliant drainage field, plus enough fall from the outlet to the field to avoid a lift pump

A buried field of perforated pipes in gravel that lets cleaned used water soak slowly into the ground, where it is not reused. The soil finishes cleaning it. It is the legal way to return the water to the ground safely. It needs no pump where the field lies lower than the treatment outlet.

## Build it

This is contracted work rather than a self-build.

- **Cost:** Low
- **Upkeep:** Seasonal
- **Skill to build:** Specialist
- **Lifespan:** Drainage field: 20-30 years before soil clogging ("biomat") reduces infiltration and the field needs rest or replacement
- **Embodied carbon:** Low
- **Space / material use:** Low
- **When it gives:** Continuous process
- **Skill to repair:** Intermediate
- **Regulation (FR example):** On-site sanitation (assainissement non collectif): the installation must be declared to and approved by the local SPANC before work starts, and is subject to periodic inspection. Arrete du 7 septembre 2009 modifie. [Source: service-public.gouv.fr](https://www.service-public.gouv.fr/particuliers/vosdroits/F447)

## Inputs

- [Treated wastewater](https://lowtechgraph.org/en/resource/treated-effluent)

## Outputs

none

## At a glance

The only option catalogued for this need so far, so there is nothing to compare it against.

## Sources

- [InspectAPedia, "Life Expectancy of a Septic Drainfield" (USDA: at least 20 years if run and maintained properly)](https://inspectapedia.com/septic/Septic_Drainfield_Life.php)

## Limitations of this page

We don’t list sizing or quantities, as the yield of each technique depends on the quality of its build. The catalogue compares options but doesn’t dimension them. Regulatory notes are indicative, with a French example, and need to be confirmed locally.