> Lowtech Graph · https://lowtechgraph.org/en/solution/mains-sewer-connection · [fr](https://lowtechgraph.org/fr/solution/raccordement-au-reseau-d-assainissement-collectif.md)  
> The catalogue content is published under CC BY-SA 4.0: use it, adapt it, credit it, and share what you build from it on the same terms.

[Toilets and sewage](https://lowtechgraph.org/en/need/blackwater-sewage-management) › [Treating it](https://lowtechgraph.org/en/need/blackwater-sewage-management/treatment)

Lowtech Graph lists low-tech options for every need of a home. Here you can compare them, find tutorials to build them, and combine them into a circular system.

# Mains sewer

Needs the grid

One of 4 ways to meet this need. Cost, carbon, footprint and rankings are relative to other solutions for the same need, not absolute.

## What your site needs

A public sewer reaching the property, and a connection permitted by the commune

Waste water from the house sent into the public sewer and treated at a works elsewhere. There is no tank, no field and nothing to maintain on the property. But if the network fails there is no fallback, and the nutrients in the waste are lost to the land.

## Build it

This solution is not buildable as a DIY project.

- **Cost:** Medium
- **Upkeep:** None
- **Skill to build:** Specialist
- **Lifespan:** Connection and buried lateral: 50+ years; the public network beyond the boundary is the utility's responsibility, not the householder's
- **Embodied carbon:** Low
- **Space / material use:** Low
- **When it gives:** Continuous process
- **Skill to repair:** Specialist
- **Regulation (FR example):** Where a public sewer is available, connection is compulsory within two years of it being commissioned (art. L1331-1 code de la sante publique), and a connection charge applies. On-site sanitation is only permitted where no public sewer serves the property. [Source: service-public.gouv.fr](https://www.service-public.gouv.fr/particuliers/vosdroits/F447)

## Inputs

- [Blackwater](https://lowtechgraph.org/en/resource/blackwater)
- [Greywater](https://lowtechgraph.org/en/resource/greywater)

## Outputs

none

## Assess it · 4 ways to meet this need

- **Mains sewer** (This page)
   Can I use it? Works in a flat · No rebuilding needed
   What does it cost me? Upfront cost: Medium · Skill to build: Specialist · Upkeep: None · Change to daily life: None · Works without the grid: No
   Choose it if the house is on the public sewer and you want nothing to maintain.
- [Septic tank + drain field](https://lowtechgraph.org/en/solution/septic-tank-drain-field)
   Can I use it? Not in a flat · No rebuilding needed
   What does it cost me? Upfront cost: Medium · Skill to build: Intermediate · Upkeep: Light · Change to daily life: Occasional · Works without the grid: Yes
   Choose it if you are off the sewer and have a garden for a drain field.
- [Constructed wetland blackwater treatment](https://lowtechgraph.org/en/solution/constructed-wetland-blackwater-treatment)
   Can I use it? Not in a flat · No rebuilding needed
   What does it cost me? Upfront cost: Medium · Skill to build: Intermediate · Upkeep: Light · Change to daily life: Occasional · Works without the grid: Yes
   Choose it if you want all your wastewater treated on site by planted beds, with no power.
- [Aerobic treatment unit / micro-station d'epuration (package plant)](https://lowtechgraph.org/en/solution/aerobic-treatment-unit-micro-station-d-epuration)
   Can I use it? Not in a flat · No rebuilding needed
   What does it cost me? Upfront cost: High · Skill to build: Specialist · Upkeep: Heavy · Change to daily life: Occasional · Works without the grid: No
   Choose it if your plot is small or wet, where a drain field would fail.

## Sources

- [Service-Public.fr, "Assainissement des eaux usées domestiques" (connection to the public sewer is compulsory where it exists)](https://www.service-public.gouv.fr/particuliers/vosdroits/F447)

## Limitations of this page

We don’t list sizing or quantities, as the yield of each technique depends on the quality of its build. The catalogue compares options but doesn’t dimension them. Regulatory notes are indicative, with a French example, and need to be confirmed locally.